Evidence PassportSample · Illustrative data

Sample Evidence Passport for a machined steel flange

A material certificate arrived, but listed a different heat from the lot record. See where the mismatch came from and why the buyer held the shipment. All records, people and dates are fictional.

Order
PO-SAMPLE-0142
Product
Machined steel flange
SKU
SAMPLE-FL100
Lot
Sample lot A
Brand
Sample Industrial Co.
Ships from
Contract factory, Asia
Spec version
FL100 spec, version C
Status
Hold pending lot traceability

Check by check

#What the spec asks forWhat the factory foundProofIssueNext step
Q1Outside diameter220 ± 0.5 mm219.7 – 220.3 mm ReceivedMeasurement sheet, 32 parts—OK
Q2Bore diameter115 ± 0.2 mm114.9 – 115.1 mm ReceivedMeasurement sheet, 32 parts—OK
Q3Hardness150–190 HB162 – 178 HB ReceivedFactory test report, 5 parts—OK
Q4Material gradeASTM A105 steelCertificate lists heat H-17. Lot A traveler lists heat H-21. FlaggedMaterial certificateView source recordsYesFactory QC to send a certificate for H-21 and reconcile the lot record
Q5Surface finishNo cracks or burrs32 of 32 photos received ReceivedInspection photos, 32 parts—OK
Q6Coating thickness60–80 µm64 – 77 µm ReceivedCoating gauge readings, 10 parts—OK
Q7Part markingPer marking spec v3Matches spec ReceivedInspection photos—OK
Q8Packaging and labelsPer packing spec v2Barcode scans; labels match ReceivedPacking photos, 3 crates—OK

The source records behind the material check

A heat number identifies a batch of metal from the mill. A certificate can be on file and still leave the grade for this lot unsupported.

mill-certificate-H17.pdf

Submitted by
Sample Factory QC (mill-issued certificate)
Created
2026-10-12 09:00 UTC
Received
2026-10-14 03:10 UTC
Lot and sample coverage
Heat H-17. No record links it to sample lot A.

lot-A-traveler-r2.pdf

Submitted by
Sample Factory QC
Created
2026-10-13 07:30 UTC
Received
2026-10-14 03:12 UTC
Lot and sample coverage
Sample lot A, 32 parts, heat H-21, FL100 spec version C.

Revision history. Traveler r2 added sample count and drawing revision. The heat stayed H-21. To challenge the entry, the buyer can request the original certificate and ask the factory to trace the marked heat to the lot.

These fictional file references illustrate the format. Available source details depend on the records supplied and the agreed scope. Evidence review does not independently authenticate files or materials.

Open issue

Material grade

Certificate heat H-17 does not match lot A traveler heat H-21. Factory QC must provide the H-21 certificate and reconcile it to lot A.

Recorded buyer decision

Hold

Sample Industrial Co. quality lead · 2026-10-14 10:00 UTC. Release requires a matching certificate and buyer review. At decision time, 7 of 8 checks had evidence on file without a flagged issue.

The PDF includes the sample disposition and pilot terms. IntelFactor reviews records. The buyer decides whether the shipment is released.