Sample Evidence Passport for a machined steel flange
A material certificate arrived, but listed a different heat from the lot record. See where the mismatch came from and why the buyer held the shipment. All records, people and dates are fictional.
- Order
- PO-SAMPLE-0142
- Product
- Machined steel flange
- SKU
- SAMPLE-FL100
- Lot
- Sample lot A
- Brand
- Sample Industrial Co.
- Ships from
- Contract factory, Asia
- Spec version
- FL100 spec, version C
- Status
- Hold pending lot traceability
Check by check
| # | What the spec asks for | What the factory found | Proof | Issue | Next step |
|---|---|---|---|---|---|
| Q1 | Outside diameter220 ± 0.5 mm | 219.7 – 220.3 mm | ReceivedMeasurement sheet, 32 parts | — | OK |
| Q2 | Bore diameter115 ± 0.2 mm | 114.9 – 115.1 mm | ReceivedMeasurement sheet, 32 parts | — | OK |
| Q3 | Hardness150–190 HB | 162 – 178 HB | ReceivedFactory test report, 5 parts | — | OK |
| Q4 | Material gradeASTM A105 steel | Certificate lists heat H-17. Lot A traveler lists heat H-21. | FlaggedMaterial certificateView source records | Yes | Factory QC to send a certificate for H-21 and reconcile the lot record |
| Q5 | Surface finishNo cracks or burrs | 32 of 32 photos received | ReceivedInspection photos, 32 parts | — | OK |
| Q6 | Coating thickness60–80 µm | 64 – 77 µm | ReceivedCoating gauge readings, 10 parts | — | OK |
| Q7 | Part markingPer marking spec v3 | Matches spec | ReceivedInspection photos | — | OK |
| Q8 | Packaging and labelsPer packing spec v2 | Barcode scans; labels match | ReceivedPacking photos, 3 crates | — | OK |
The source records behind the material check
A heat number identifies a batch of metal from the mill. A certificate can be on file and still leave the grade for this lot unsupported.
mill-certificate-H17.pdf
- Submitted by
- Sample Factory QC (mill-issued certificate)
- Created
- 2026-10-12 09:00 UTC
- Received
- 2026-10-14 03:10 UTC
- Lot and sample coverage
- Heat H-17. No record links it to sample lot A.
lot-A-traveler-r2.pdf
- Submitted by
- Sample Factory QC
- Created
- 2026-10-13 07:30 UTC
- Received
- 2026-10-14 03:12 UTC
- Lot and sample coverage
- Sample lot A, 32 parts, heat H-21, FL100 spec version C.
Revision history. Traveler r2 added sample count and drawing revision. The heat stayed H-21. To challenge the entry, the buyer can request the original certificate and ask the factory to trace the marked heat to the lot.
These fictional file references illustrate the format. Available source details depend on the records supplied and the agreed scope. Evidence review does not independently authenticate files or materials.
Open issue
Material grade
Certificate heat H-17 does not match lot A traveler heat H-21. Factory QC must provide the H-21 certificate and reconcile it to lot A.
Recorded buyer decision
Hold
Sample Industrial Co. quality lead · 2026-10-14 10:00 UTC. Release requires a matching certificate and buyer review. At decision time, 7 of 8 checks had evidence on file without a flagged issue.
The PDF includes the sample disposition and pilot terms. IntelFactor reviews records. The buyer decides whether the shipment is released.
Scope a $2,500 Pilot